1 June 2017 EVALUATION OF THE I-STAT PORTABLE CLINICAL ANALYZER FOR MEASUREMENT OF IONIZED CALCIUM AND SELECTED BLOOD CHEMISTRY VALUES IN ASIAN ELEPHANTS (ELEPHAS MAXIMUS)
Danielle K. Tarbert, Erica Behling-Kelly, Heather Priest, Sara Childs-Sanford
Author Affiliations +
Abstract

Thei-STAT® portable clinical analyzer (PCA) provides patient-side results for hematologic, biochemical, and blood gas values when immediate results are desired. This analyzer is commonly used in nondomestic animals; however, validation of this method in comparison with traditional benchtop methods should be performed for each species. In this study, the i-STAT PCA was compared with the Radiometer ABL 800 Flex benchtop analyzer using 24 heparinized whole blood samples obtained from healthy E. maximus. In addition, the effect of sample storage was evaluated on the i-STAT PCA. Analytes evaluated were hydrogen ion concentration (pH), glucose, potassium (K ), sodium (Na ), bicarbonate (HCO3), total carbon dioxide (TCO2), partial pressure of carbon dioxide (PCO2), and ionized calcium (iCa2 ). Statistical analysis using correlation coefficients, Passing-Bablok regression analysis, and Bland-Altman plots found good agreement between results from samples run immediately after phlebotomy and 4 hr postsampling on the i-STAT PCA with the exception of K , which is known to change with sample storage. Comparison of the results from the two analyzers at 4 hr postsampling found very strong or strong correlation in all values except K , with statistically significant bias in all values except glucose and PCO2. Despite bias, mean differences assessed via Bland-Altman plots were clinically acceptable for all analytes excluding K . Within the reference range for iCa2 , the iCa2 values obtained by the i-STAT PCA and Radiometer ABL 800 Flex were close in value, however in light of the constant and proportionate biases detected, overestimation at higher values and underestimation at lower values of iCa2 by the i-STAT PCA would be of potential concern. This study supports the use of the i-STAT PCA for the evaluation of these analytes, with the exception of K , in the Asian elephant.

Copyright 2017 by American Association of Zoo Veterinarians
Danielle K. Tarbert, Erica Behling-Kelly, Heather Priest, and Sara Childs-Sanford "EVALUATION OF THE I-STAT PORTABLE CLINICAL ANALYZER FOR MEASUREMENT OF IONIZED CALCIUM AND SELECTED BLOOD CHEMISTRY VALUES IN ASIAN ELEPHANTS (ELEPHAS MAXIMUS)," Journal of Zoo and Wildlife Medicine 48(2), 319-327, (1 June 2017). https://doi.org/10.1638/2016-0150R1.1
Accepted: 1 February 2017; Published: 1 June 2017
KEYWORDS
Asian elephant
biochemical analytes
ionized calcium
i-STAT
method comparison
venous blood gas
RIGHTS & PERMISSIONS
Get copyright permission
Back to Top