10 September 2019 Deciding between an X-Ray and 137Cs Irradiator – It's not just about Energy Spectra
Mark K. Murphy, Jacob Kamen
Author Affiliations +
Abstract

Irradiators utilizing radioactive cesium-137 (137Cs) or cobalt-60 (60Co) gamma-ray sources have been used for biological applications for many decades. These applications include irradiation of much of the nation's blood supply and radiation biology research. In 2005, the U.S. Nuclear Regulatory Commission was assigned the task of preventing the misuse of radioactive materials by persons with malicious intentions; gamma-ray sources, in particular, were given high priority. This resulted in increased security requirements, including constant surveillance, controlled access and personnel background checks. As a result of such regulations being introduced, organizations considering the purchase of a gamma-ray irradiator for the first time or as a replacement to an existing one due to radioactive decay, are now looking into alternative technologies, primarily an X-ray irradiator. To make an educated decision on whether a particular type of X-ray irradiator is of sufficient equivalency to a particular type of 137Cs irradiator for specific applications, one must rely on relevant published comparison studies from other researchers, or perform the comparison studies on their own. This work focuses on the comparison of the radiation physics aspects of two 137Cs irradiator models and three X-ray irradiator models, for the purpose of determining whether the X-ray irradiator models could validly replace the 137Cs irradiator models for certain applications. Although evaluating the influence of relative biological effectiveness (RBE) differences among irradiators could be part of this study, that has been left for a related publication focused on the theoretical aspects of this topic. These evaluations were performed utilizing 47-g and 120-g tissue-equivalent rodent dosimetry phantoms. Our results indicate that, depending upon the user's dose uncertainty budget and maximum areal density of specimens to be irradiated, the RS 2000 160 kVp X-ray irradiator, X-RAD160 X-ray irradiator or X-RAD320 X-ray irradiator could successfully replace a 137Cs irradiator. Technically, any X-ray irradiator model providing similar irradiation geometry, and average energy similar to or higher than these three X-ray models, could also successfully replace a 137Cs irradiator. The results also reveal that differences in inherent source geometry, field geometry and irradiation geometry can counter some of the influence due to differences in energy spectrum. Our goal is that this publication be used as a guide for other similar studies, providing investigators with information on important details that can make the difference between strong and weak comparison conclusions.

©2019 by Radiation Research Society. All rights of reproduction in any form reserved.
Mark K. Murphy and Jacob Kamen "Deciding between an X-Ray and 137Cs Irradiator – It's not just about Energy Spectra," Radiation Research 192(5), 493-506, (10 September 2019). https://doi.org/10.1667/RR15395.1
Received: 1 April 2019; Accepted: 29 July 2019; Published: 10 September 2019
RIGHTS & PERMISSIONS
Get copyright permission
Back to Top