How to translate text using browser tools
15 July 2016 The use of nondestructive sensors to assess nitrogen status in potted dianthus (Dianthus chinensis L.) production
Rania Basyouni, Bruce L. Dunn, Carla Goad
Author Affiliations +
Abstract

Optical sensors are a fast and nondestructive new technology used to estimate plant chlorophyll content by measuring leaf reflectance or absorbance of light. The objective of this study was to evaluate the reliability of normalized difference vegetative index (NDVI) values calculated by the GreenSeeker™ hand held sensor as an indirect indicator of dianthus (Dianthus chinensis L.) N status, and investigate nutrient supplementation on deficient ‘Telstar™ White’ and ‘Telstar™ Red Picotee’ plants. Pots were supplemented with 0, 5, 10, 15, and 20 g of 15N-3.9P-10K controlled release fertilizer (CRF). Soil and plant analysis development (SPAD) chlorophyll meter, GreenSeeker™ NDVI sensor, and atLEAF meter readings were recorded for four consecutive weeks. At 49 d after planting (DAP), the 0 and 5 g treatments were found deficient and half of the pots were supplemented with extra fertilizer for treatment correction (C 0 and C 5, respectively). The SPAD and atLEAF readings showed stronger correlation to actual leaf N concentration compared with the GreenSeeker™. The GreenSeeker™ readings were less correlated with leaf N concentration at early stages of establishment due to the plants’ small size and background noise, as well as at later stages of establishment due to anthesis. Dianthus quality responses generally increased as fertilizer rates increased. The additional correction treatment showed a significant improvement in C 5 and no significant improvement on C 0, indicating that the correction treatment was beneficial for dianthus when initial amount of fertilizer was applied.

Copyright remains with the author(s) or their institution(s). Permission for reuse (free in most cases) can be obtained from RightsLink.
Rania Basyouni, Bruce L. Dunn, and Carla Goad "The use of nondestructive sensors to assess nitrogen status in potted dianthus (Dianthus chinensis L.) production," Canadian Journal of Plant Science 97(1), 44-52, (15 July 2016). https://doi.org/10.1139/cjps-2016-0059
Received: 24 February 2016; Accepted: 1 June 2016; Published: 15 July 2016
JOURNAL ARTICLE
9 PAGES

This article is only available to subscribers.
It is not available for individual sale.
+ SAVE TO MY LIBRARY

KEYWORDS
atLEAF
atLEAF
capteurs optiques
CRF
engrais à libération lente
IVDN
NDVI
RIGHTS & PERMISSIONS
Get copyright permission
Back to Top