How to translate text using browser tools
31 December 2013 ELECTROCARDIOGRAMS OF BOTTLENOSE DOLPHINS (TURSIOPS TRUNCATUS) OUT OF WATER: HABITUATED COLLECTION VERSUS WILD POSTCAPTURE ANIMALS
Craig A. Harms, Eric D. Jensen, Forrest I. Townsend, Larry J. Hansen, Lori H. Schwacke, Teresa K. Rowles
Author Affiliations +
Abstract

Electrocardiography (ECG) was performed on captured free-ranging bottlenose dolphins (Tursiops truncatus) during a health assessment exercise and compared with that of a Navy collection of dolphins habituated to handling out of water in order to assess possible cardiovascular impacts of capture and handling. Six-lead recordings (I, II, III, aVr, aVl, and aVf) in the frontal plane and direct thorax leads were collected from both groups, with a modified base-apex lead additionally employed with the Navy collection dolphins. Measured and calculated parameters included amplitudes of P, R, S, and T waves and total QRS complex; T:S and T:QRS ratios; heart rate; durations of P wave; QRS complex, PR, QT, and RR intervals; maximum minus minimum RR interval; ST segment elevation-depression; and mean electrical axis (MEA). Physiologically minor but statistically significant differences were detected in S wave amplitude, PR interval, QRS duration, and MEA. The PR interval, QRS duration, and S wave amplitude were slightly greater and the MEA oriented slightly rightward in wild postcapture dolphins compared to Navy collection dolphins. There were no differences in heart rate or maximum minus minimum RR interval, which serves as a proxy for the expected sinus arrhythmia of dolphins. The base-apex lead resulted in greater QRS amplitude than lead II, as expected for the category B ventricular activation of dolphins. The left-side direct thorax lead was more consistent than that of the right side. Clinically, ECG was a useful adjunct to auscultation and thoracic palpation for monitoring heart rate and rhythm and generated a record for archiving. Safe capture and handling protocols in place, under which dolphins are immediately returned to the water at progressive signs of distress, may make cardiovascular decompensation less likely to be detected by ECG. It appears that the dolphin cardiovascular system compensates suitably well to capture, as measured by ECG under the conditions of this study.

American Association of Zoo Veterinarians
Craig A. Harms, Eric D. Jensen, Forrest I. Townsend, Larry J. Hansen, Lori H. Schwacke, and Teresa K. Rowles "ELECTROCARDIOGRAMS OF BOTTLENOSE DOLPHINS (TURSIOPS TRUNCATUS) OUT OF WATER: HABITUATED COLLECTION VERSUS WILD POSTCAPTURE ANIMALS," Journal of Zoo and Wildlife Medicine 44(4), 972-981, (31 December 2013). https://doi.org/10.1638/2013-0093.1
Received: 1 May 2013; Published: 31 December 2013
KEYWORDS
capture effects
Dolphin
electrocardiogram
health assessment
Tursiops truncatus
RIGHTS & PERMISSIONS
Get copyright permission
Back to Top