How to translate text using browser tools
2 August 2024 Comparing the biological effectiveness of low energy 100 kV and high energy 5 MeV X-rays against Oriental fruit fly (Diptera: Tephritidae)
Peter A. Follett, Thomas J. Fezza, Nicolas C. Ladizinsky, Pei-Shih Liang
Author Affiliations +
Abstract

Radioisotope irradiators (using cesium-137 or cobalt-60) are used as sources of ionizing radiation to control quarantine or phytosanitary insect pests in internationally traded fresh commodities and to sterilize insects used in sterile insect release programs. There are institutional initiatives to replace isotopic irradiators (producing γ-rays) with lower-energy X-ray machines due to concerns about radiological terrorism and increasingly stringent regulations on the movement of radioisotopes. Questions remain about whether the biological effects of low-energy X-rays are comparable to those of γ-rays since differences in energy levels and dose rates of X-rays may have different efficacies. We compared adult emergence, flight ability, and adult survival in the Oriental fruit fly, Bactrocera dorsalis (Hendel) (Diptera: Tephritdae), after irradiation of third instar larvae with 100 kV or 5 MeV (5,000 kV) X-rays at 20 and 40 Gy in replicated studies. At 20 Gy, the adult emergence rate was significantly lower after irradiation with 100 kV compared to 5 MeV X-rays, suggesting higher efficacy at the lower energy level. In a follow-up study using 100 kV X-rays, applying 20 Gy using a slow dose rate (0.24 Gy min–1) resulted in significantly higher adult emergence than did a fast dose rate (3.3 Gy min–1), suggesting lower efficacy. Although our study suggests higher efficacy of low energy 100 kV X-rays, there is uncertainty in measuring the dose from an X-ray tube operating at 100 kV using an ionization chamber; we discuss how this uncertainty may change the interpretation of the results. Using a 100 kV X-ray irradiator to develop a phytosanitary treatment may underestimate the dose required for insect control using commercial high-energy γ-ray or X-ray systems.

Peter A. Follett, Thomas J. Fezza, Nicolas C. Ladizinsky, and Pei-Shih Liang "Comparing the biological effectiveness of low energy 100 kV and high energy 5 MeV X-rays against Oriental fruit fly (Diptera: Tephritidae)," Journal of Economic Entomology 117(5), 1815-1822, (2 August 2024). https://doi.org/10.1093/jee/toae169
Received: 8 December 2023; Accepted: 16 July 2024; Published: 2 August 2024
JOURNAL ARTICLE
8 PAGES

This article is only available to subscribers.
It is not available for individual sale.
+ SAVE TO MY LIBRARY

KEYWORDS
Bactrocera dorsalis
dosimetry
low-energy X-ray
phytosanitary irradiation
RBE
RIGHTS & PERMISSIONS
Get copyright permission
Back to Top